There is an alternative protein purification system
Prices start from £20K
Discounts available for Trade-ins on any old GE /Amersham Akta system.
If you would like a demonstration, please contact below.
Main application:
Protein purification system is mainly used in biopharmaceutical fields such as monoclonal antibodies, recombinant proteins, vaccines, biochemical drugs, antibiotics, natural products and polysaccharides. It is used for the separation and purification of downstream processes of biological products
Product features and advantages:
Unique CDsystem chromatography workstation software
Unique CDsystem is a powerful, advanced and stable chromatographic data management system
Configuration list of Autopure series protein purification system:
AutoPure series:
Model | Article number | Description |
Unique AutoPure25-L1 | 04-004-002-250 | 1、 Infusion pump: 1.1 Binary gradient bio inert infusion pump *Flow rate: Range: 0.001-25.000 ml/min Velocity accuracy: 1.2% Flow rate precision: 0.5% *Pressure: 0-27.5 Mpa *Dynamic mixer: 2ml, panel mounted, easy to replace 2、 Automatic Iinjection valve 2.1: automatic sample injection valve, which can be controlled by software, and supports: load / inject / waste 2.2: 1ml sample loop 3、 280nm fixed wavelength detector 3.1: 280nm imported led detector, service life: 8000hr 3.2: Noise: ± 2x10-5Abs 3.3: 2 mm flow cell 4: Conductivity detector: 4.1: range: 0.000-999.99 mS / cm 4.2: accuracy: ±0.02Ms/cm or ±2% 5: Protein purification chromatography workstation (including brand computer, software and communication module, chromatography workstation software) |
Unique AutoPure25-M402 | 04-004-002-252 | 1、 Infusion pump: 1.1 binary gradient bio inert infusion pump *Flow rate: Range: 0.001-25.000ml/min Velocity accuracy: 1.2% Flow rate precision: 0.5% *Pressure: 0-27.5 Mpa *Dynamic mixer: 2ml, panel mounted, easy to replace 2、 Automatic injection valve 2.1: automatic sample injection valve, which can be controlled by software, and supports: load / inject / waste 2.2: 1ml sample loop 3、 DAD detector 3.1: 200-400nm imported dad detector 3.2:Noise: ± 1x10-4Abs 3.3: 2mm flow cell 4: Conductivity detector: 4.1: Range: 0.001-999.99 mS / cm 4.2: Accuracy: ±0.02Ms/cm or ±2% 5: Protein purification chromatography workstation (including brand computer, software and communication module, chromatography workstation software) |
AutoPure100 series:
Model | Article number | Description |
Unique AutoPure100-L1 | 04-004-002-100 | 1、 Infusion pump: 1.1 Binary gradient bio inert infusion pump *Flow rate: Range: 0.001-100.000 ml/min Velocity accuracy: 1.2% Flow rate precision: 0.5% *Pressure: 0-10 Mpa *Dynamic mixer: 2ml, panel mounted, easy to replace 2、 Automatic injection valve 2.1: Automatic sample injection valve, which can be controlled by software, and supports load / inject / waste 2.2: 1ml sample loop 3、 280nm fixed wavelength detector 3.1: 280nm imported led detector, service life: 800hr 3.2: noise: ± 2x10-5Abs 3.3: 2mm flow cell 4: Conductivity detector: 4.1: Range: 0.000-999.99 mS / cm 4.2: Accuracy: ±0.02Ms/cm or ±2% 5: Protein purification chromatography workstation (including brand computer, software and communication module, chromatography workstation software) |
Unique AutoPure100-M402 | 04-004-002-102 | 1、 Infusion pump: 1.1 Binary gradient bio inert infusion pump *Flow rate: Range: 0.001-100.000ml/min Velocity accuracy: 1.2% Flow rate precision: 0.5% *Pressure: 0-10mpa *Dynamic mixer: 2ml, panel mounted, easy to replace 2、 Automatic injection valve 2.1: Automatic sample injection valve, which can be controlled by software, and supports load / inject / waste 2.2: 1ml sample loop 3、 DAD detector 3.1: 200-400nm imported DAD detector 3.2: Noise: ± 1x10-4Abs 3.3: 2 mm flow cell 4: Conductivity detector: 4.1: Range: 0.001-999.99 mS / cm 4.2: Accuracy: ±0.02 mS/cm or ±2% 5: Protein purification chromatography workstation (including brand computer, software and communication module, chromatography workstation software) |
AutoPure150 series:
Model | Article number | Description |
Unique AutoPure150-L1 | 04-004-002-150 | 1、 Infusion pump: 1.1 Binary gradient bio inert infusion pump *Flow rate: Range: 0.001-150.000ml/min Velocity accuracy: 1.2% Flow rate precision: 0.5% *Pressure: 0-5 Mpa *Dynamic mixer: 2ml, panel mounted, easy to replace 2、 Automatic sampling valve 2.1: Automatic sample injection valve, which can be controlled by software, and supports load / inject / waste 2.2: 1ml sample 3、 280nm fixed wavelength detector 3.1: 280nm imported led detector, service life: 8000hr 3.2: Noise: ± 2x10-5Abs 3.3: 2mm flow cell 4: Conductivity detector: 4.1: Range: 0.000-999.99 mS / cm 4.2: Accuracy: ±0.02 mS/cm or ±2% 5: Protein purification chromatography workstation (including brand computer, software and communication module, chromatography workstation software) |
Unique AutoPure150-M402 | 04-004-002-152 | 1、 Infusion pump: 1.1 Binary gradient bio inert infusion pump *Flow rate: Range: 0.001-150.000 ml/min Velocity accuracy: 1.2% Flow rate precision: 0.5% *Pressure: 0-5 Mpa *Dynamic mixer: 2ml, panel mounted, easy to replace 2、 Automatic sampling valve 2.1: Automatic sample injection valve, which can be controlled by software, and supports load / inject / waste 2.2: 1ml sample loop 3、 DAD detector 3.1: 200-400nm imported dad detector 3.2: Noise: ± 1x10-4 Abs 3.3: 2mm flow cell 4: Conductivity detector: 4.1: range: 0.001-999.99 mS / cm 4.2: accuracy: ±0.02 mS/cm or ±2% 5: Protein purification chromatography workstation (including brand computer, software and communication module, chromatography workstation software) |
AutoPure300 series:
Model | Article number | Description |
Unique AutoPure300-L1 | 04-004-002-300 | 1、 Infusion pump: 1.1 Binary gradient bio inert infusion pump *Flow rate: Range: 0.001-300.000 ml/min Velocity accuracy: 2% Flow rate precision: 0.5% *Pressure: 0-5 Mpa *Dynamic mixer: 5ml, panel mounted, easy to replace 2、 Automatic injection valve 2.1: Automatic sample injection valve, which can be controlled by software, and supports load / inject / waste 2.2: 1ml sample loop 3、 280nm fixed wavelength detector 3.1: 280nm imported led detector, service life: 8000hr 3.2: Noise: ± 2x10-5Abs 3.3: 2 mm flow cell 4: Conductivity detector: 4.1: Range: 0.000-999.99 mS / cm 4.2: Accuracy: ±0.02 mS/cm or ±2% 5: Protein purification chromatography workstation (including brand computer, software and communication module, chromatography workstation software) |
Unique AutoPure300-M402 | 04-004-002-302 | 1、 Infusion pump: 1.1 binary gradient bio inert infusion pump *Flow rate: Range: 0.001-300.000ml/min Velocity accuracy: 2% Flow rate precision: 0.5% *Pressure: 0-5 Mpa *Dynamic mixer: 5ml, panel mounted, easy to replace 2、 Automatic injection valve 2.1: automatic sample injection valve, which can be controlled by software, and supports load / inject / waste 2.2: 1ml sample loop 3、 DAD detector 3.1: 200-400nm imported DAD detector 3.2: Noise: ± 1x10-4Abs 3.3: 2 mm flow cell 4: Conductivity detector: 4.1: range: 0.001-999.99 mS / cm 4.2: accuracy: ±0.02 mS/cm or ±2% 5: Protein purification chromatography workstation (including brand computer, software and communication module, chromatography workstation software) |
Optional configuration:
Model | Article number | Description |
AirS01-H | 03-001-003-002 | Bubble sensor for monitoring sample loading |
CPV02RX | 03-001-001-002 | Single column position valve, supporting downward / upward / bypass |
MSV04 | 03-001-002-003 | Mobile phase selection module, 4 channels |
MSV10 | 03-001-002-002 | Mobile phase selection module, 10 channels |
DAD604 | 03-002-001-003 | Imported four channel DAD detector Wavelength range: 200-600nm Noise: ± 0.04 mAu Drift: 1x10-3 Au / HR |
DAD804 | 03-002-001-004 | Imported four channel DAD detector Wavelength range: 200-800nm Noise: ± 0.04mAu Drift: 1x10-3 Au / HR |
pH detector | 03-004-001-001 | pH detector 0-14 (best for ph2-12), temperature compensation Dead volume of circulation tank: 76μl |
OV02 | 03-003-001-001 | Outlet valve (large volume collection valve), 1 collection channel and 1 waste liquid |
OV10 | 03-003-001-001 | Outlet valve (large volume collection valve), 9 collection channels and 1 waste liquid |
Frac-02 | 03-003-001-003 | Fraction collector Support 2 collection racks 1. 3x7, 30mm, 21 tubes, 2 2. 5x12, 16mm, 60 tubes, 2 3. 6x15, 13mm, 90 pipe, 2 4. 96 hole plate, 4 |
It’s easy to contact us. Simply fill in the form below and we’ll aim to respond within one hour (during office hours).
Copyright © 2022 Holmes Analytical. Website design by Lewis Jenkins.